Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Braz. j. biol ; 84: e256190, 2024. tab, graf, mapas
Article in English | LILACS, VETINDEX | ID: biblio-1364523

ABSTRACT

Particulate matter (PM) is a major air pollutant causing serious health problems. The aim of the present study was to find out concentration of PM in ambient air and its associated health risk in Haripur city, Pakistan. Twenty-three samples were taken at various educational institutes, hospitals, recreational areas and industries in Haripur city. Concentration of PM2.5 (µg/m3) and PM10 (µg/m3) was measured with Youngteng YT-HPC 3000A portable PM counter. The results revealed that values of both PM2.5 and PM10 were above the permissible limits (35 µg/m3 for PM2.5 and 150 µg/m3 for PM10) set by Environmental Protection Agency Pakistan (Pak-EPA) in all the educational institutes, hospitals, recreational areas and industries investigated. Furthermore, significant (p<0.05) variation was found in the concentration of both PM2.5 and PM10 in all the educational institutes, hospitals, recreational areas, and industries studied. The concentration of PM2.5 was positively correlated with the concentration of PM10 in all the sampling sites. Therefore, from 1-14 scale standard of health index, the values of PM2.5 and PM10 exhibited that the ambient air quality of Haripur city Pakistan is under high risk. If the regulatory authorities such as Environmental Protection Agency, Health Department and Local Government monitor PM pollution in different settings of Haripur city, then a decrease can be possible in the pollution level. The remedies that can be taken to overcome the problem of ambient air pollution such as PM are plantation of trees at the sites where there are higher levels of air pollutants and use of masks on personal protection basis along with implementation of pollution control system in industries of Hattar Industrial Estate Haripur city, Pakistan.


O material particulado (MP) é um importante poluente do ar que causa sérios problemas de saúde. O objetivo do presente estudo foi descobrir a concentração de MP no ar ambiente e sua associação com o risco à saúde na cidade de Haripur, Paquistão. Vinte e três amostras foram coletadas em várias instituições de ensino, hospitais, áreas recreativas e indústrias na cidade de Haripur. A concentração de MP2,5 (µg/m3) e MP10 (µg/m3) foi medida por meio do contador de MP portátil Youngteng YT-HPC 3000A. Os resultados revelaram que os valores de MP2,5 e MP10 estavam acima dos limites permitidos (35 µg/m3 para MP2,5 e 150 µg/m3 para MP10) estabelecidos pela Agência de Proteção Ambiental do Paquistão (Pak-EPA) em todas as instituições de ensino, hospitais, áreas recreativas e indústrias investigadas. Além disso, foi encontrada variação significativa (p < 0,05) na concentração de MP2,5 e MP10 em todos os locais estudados. A concentração de MP2,5 correlacionou-se positivamente com a concentração de MP10 em todos os locais de amostragem. Portanto, a partir da escala padrão 1-14 do índice de saúde, os valores de MP2,5 e MP10 mostraram que a qualidade do ar ambiente na cidade de Haripur, Paquistão, está sob alto risco. Se as autoridades reguladoras, como a Pak-EPA, o Departamento de Saúde e o governo local, monitorarem a poluição por MP em diferentes configurações da cidade de Haripur, pode ser que haja uma diminuição no nível de poluição. As medidas que podem ser tomadas para superar o problema da poluição do ar ambiente, como o MP, são o plantio de árvores nos locais onde há maiores níveis de poluentes atmosféricos, o uso de máscaras e a implantação de sistema de controle de poluição nas propriedades industriais de Hattar, na cidade Haripur, Paquistão.


Subject(s)
Health Risk , Air Pollutants , Air Pollution , Particulate Matter , Pakistan
2.
Braz. j. biol ; 842024.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469378

ABSTRACT

Abstract Particulate matter (PM) is a major air pollutant causing serious health problems. The aim of the present study was to find out concentration of PM in ambient air and its associated health risk in Haripur city, Pakistan. Twenty-three samples were taken at various educational institutes, hospitals, recreational areas and industries in Haripur city. Concentration of PM2.5 (µg/m3) and PM10 (µg/m3) was measured with Youngteng YT-HPC 3000A portable PM counter. The results revealed that values of both PM2.5 and PM10 were above the permissible limits (35 µg/m3 for PM2.5 and 150 µg/m3 for PM10) set by Environmental Protection Agency Pakistan (Pak-EPA) in all the educational institutes, hospitals, recreational areas and industries investigated. Furthermore, significant (p 0.05) variation was found in the concentration of both PM2.5 and PM10 in all the educational institutes, hospitals, recreational areas, and industries studied. The concentration of PM2.5 was positively correlated with the concentration of PM10 in all the sampling sites. Therefore, from 1-14 scale standard of health index, the values of PM2.5 and PM10 exhibited that the ambient air quality of Haripur city Pakistan is under high risk. If the regulatory authorities such as Environmental Protection Agency, Health Department and Local Government monitor PM pollution in different settings of Haripur city, then a decrease can be possible in the pollution level. The remedies that can be taken to overcome the problem of ambient air pollution such as PM are plantation of trees at the sites where there are higher levels of air pollutants and use of masks on personal protection basis along with implementation of pollution control system in industries of Hattar Industrial Estate Haripur city, Pakistan.


Resumo O material particulado (MP) é um importante poluente do ar que causa sérios problemas de saúde. O objetivo do presente estudo foi descobrir a concentração de MP no ar ambiente e sua associação com o risco à saúde na cidade de Haripur, Paquistão. Vinte e três amostras foram coletadas em várias instituições de ensino, hospitais, áreas recreativas e indústrias na cidade de Haripur. A concentração de MP2,5 (µg/m3) e MP10 (µg/m3) foi medida por meio do contador de MP portátil Youngteng YT-HPC 3000A. Os resultados revelaram que os valores de MP2,5 e MP10 estavam acima dos limites permitidos (35 µg/m3 para MP2,5 e 150 µg/m3 para MP10) estabelecidos pela Agência de Proteção Ambiental do Paquistão (Pak-EPA) em todas as instituições de ensino, hospitais, áreas recreativas e indústrias investigadas. Além disso, foi encontrada variação significativa (p 0,05) na concentração de MP2,5 e MP10 em todos os locais estudados. A concentração de MP2,5 correlacionou-se positivamente com a concentração de MP10 em todos os locais de amostragem. Portanto, a partir da escala padrão 1-14 do índice de saúde, os valores de MP2,5 e MP10 mostraram que a qualidade do ar ambiente na cidade de Haripur, Paquistão, está sob alto risco. Se as autoridades reguladoras, como a Pak-EPA, o Departamento de Saúde e o governo local, monitorarem a poluição por MP em diferentes configurações da cidade de Haripur, pode ser que haja uma diminuição no nível de poluição. As medidas que podem ser tomadas para superar o problema da poluição do ar ambiente, como o MP, são o plantio de árvores nos locais onde há maiores níveis de poluentes atmosféricos, o uso de máscaras e a implantação de sistema de controle de poluição nas propriedades industriais de Hattar, na cidade Haripur, Paquistão.

3.
Rio de Janeiro; s.n; 2023. 272f p. ilus.
Thesis in Portuguese | LILACS | ID: biblio-1532187

ABSTRACT

Esta tese investiga a produção e circulação de evidências científicas sobre a transmissão do SARS-CoV-2, com ênfase no debate científico em torno da transmissão viral por aerossóis e a implicação de diferentes entendimentos nas práticas de prevenção adotadas ao redor do mundo. De cunho etnográfico, a pesquisa foi conduzida a partir da hashtag #covidisairborne, de importante repercussão entre cientistas e ativistas na rede social Twitter, e analisou diversos materiais digitais como artigos científicos, entrevistas, newsletters e tuítes publicados sobre o tema na rede conforme circulavam no campo, além de acompanhar o trabalho de um laboratório de pesquisa em aerossóis. A chegada da covid teria intensificado a disputa em torno das formas de transmissão viral, transformando-a em questão pública com repercussão nas práticas de proteção disseminadas durante a pandemia. Diante das evidências científicas relacionadas à transmissão, os fatos científicos se apresentam de forma contextual e implicada em distintos discursos e intenções para a condução da crise sanitária. A pandemia de covid teria acelerado o reconhecimento da qualidade do ar interno como um problema de saúde pública que chama a atenção para o ar que respiramos, e as estratégias para a mitigação dos riscos associados ao "novo normal" precisam ser informadas por princípios de justiça social e direito à saúde. (AU)


This work investigates the production and circulation of scientific evidence on the transmission of SARS-CoV-2, with an emphasis on the scientific debate surrounding aerosol viral transmission and the implications of different understandings in prevention practices adopted around the world. Ethnographically driven, the research was conducted from the hashtag #covidisairborne, which had significant repercussion among scientists and activists on the social media platform Twitter, and analyzed various digital materials such as scientific articles, interviews, newsletters, and tweets published on the network as they circulated in the field, as well as following the work of an aerosol research laboratory. The advent of covid is said to have intensified the dispute over the modes of viral transmission, turning it into a public issue with repercussions on the disease prevention practices disseminated during the pandemic. In the face of scientific evidence related to transmission, scientific facts present themselves in a contextual manner and are implicated in different discourses and intentions for managing the health crisis. The covid pandemic is said to have accelerated the recognition of indoor air quality as a public health issue that draws attention to the air we breathe, and strategies for mitigating risks associated with the "new normal" need to be informed by principles of social justice and the right to health. (AU)


Subject(s)
Air Pollution, Indoor , Evidence-Based Medicine , COVID-19/prevention & control , Respiratory Aerosols and Droplets , Social Justice , Health Law , Personal Protective Equipment , Online Social Networking
4.
Eng. sanit. ambient ; 25(3): 521-530, maio-jun. 2020. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1133793

ABSTRACT

RESUMO A intensificação das atividades industriais e o aumento das emissões veiculares têm contribuído significantemente para o aumento da poluição atmosférica nos centros urbanos. Neste trabalho, avaliou-se a qualidade do ar na área do distrito industrial de Maracanaú, no estado do Ceará, importante área industrial da Região Nordeste do Brasil. As amostragens foram realizadas durante o período de novembro de 2015 a abril de 2016, totalizando 30 coletas com duração de 24 h cada. Realizaram-se coletas para poluentes, como o material particulado total (PTS) e inalável (MP10), NO2, SO2, O3 e metais pesados (Sb, Cd, Pb, Cu, Fe, Mn, Ni e Zn) associados ao PTS e ao MP10. O O3 foi determinado por absorção no ultravioleta (254 nm), e estimaram-se as concentrações dos metais por espectroscopia de absorção atômica. Os valores médios observados para os poluentes foram de: 51,3 µg/m3 de PTS; 46,1 µg/m3 de MP10; 8,9 µg/m3 de SO2; 8,3 µg/m3 de NO2; 38,5 µg/m3 para O3 em 8 horas e 48,4 µg/m3 para O3 em 1 hora. Para os metais, o Fe (14,9 µg/m3) foi o mais abundante em ambos os particulados. Todos os parâmetros encontram-se em conformidade com os valores estabelecidos pela legislação brasileira, e somente o MP10 apresentou em 16,7% das amostras concentrações acima (média de 74,5 µg/m3) do recomendado pela Organização Mundial da Saúde. Em geral, a qualidade do ar na área industrial em estudo pode ser considerada boa, segundo os valores de índice de qualidade do ar (IQAr) recomendado pela agência de proteção ambiental americana.


ABSTRACT The intensification of industrial activities and the increase in vehicular emissions have contributed significantly to the increase in atmospheric pollution in urban centers. In this context, the present study aimed to monitor the air quality in the area of Maracanaú Industrial District, in the state of Ceará, an important industrial area in northeastern region of Brazil. Samples were collected during 24 h from November 2015 to April 2016 for pollutants such as total suspended (TSP) and inhalable particle materials (PM10), NO2, SO2, O3 and heavy metals (Sb, Cd, Pb, Cu, Fe, Mn, Ni, and Zn) associated with TSP and PM10. Ozone (O3) was determined by ultraviolet absorption (254 nm) and the concentration of heavy metals were estimated by atomic absorption spectroscopy. The mean values observed for the pollutant concentrations were: 51.3 μg/m3 for TSP; 46.1 μg/m3 for PM10; 8.9 μg/m3 for SO2; 8.3 μg/m3 for NO2; 38.5 μg/m3 for O3 in 8 hours and 48.4 μg/m3 for O3 in 1 hour. Among metals, Fe (14.9 µg/m3) was the most abundant species in both particulates. All the parameters analyzed are in accordance with the values established by the Brazilian legislation and only PM10 are above the recommended by the World Health Organization in 16.7 % of the samples (mean 74.5 μg/m3). In general, the air quality in the industrial area under study can be considered good, according to the estimates of the air quality index (AQI) recommended by the US Environmental Protection Agency.

5.
Ciênc. Saúde Colet. (Impr.) ; 24(8): 3079-3088, ago. 2019. graf
Article in Portuguese | LILACS | ID: biblio-1011896

ABSTRACT

Resumo A poluição do ar em ambientes fechados é agravada pela queima de lenha em fogões rústicos e ambientes pouco ventilados. A exposição aos poluentes emitidos por este tipo de combustível resulta no aumento da morbidade e da mortalidade. No Brasil, os estudos e as estimativas são escassos. Visando entender esta problemática, o objetivo deste trabalho foi investigar o uso de lenha utilizando as séries de dados das agências governamentais para estimar o número de pessoas expostas. Os resultados apontam que a lenha é o segundo combustível mais usado para cozinhar, sendo utilizada por uma parcela significativa da população, em torno de 30 milhões de brasileiros. Um fator decisivo no maior uso deste combustível é o nível socioeconômico da população associada ao preço do gás liquefeito de petróleo (GLP). Os estudos realizados no país registraram concentrações altas de partículas durante a queima da lenha, excedendo os limites sugeridos pela Organização Mundial da Saúde (OMS). Também foram observadas associações entre a exposição aos poluentes gerados pela queima e o agravamento dos mais diversos problemas de saúde, dentre eles doenças respiratórias e câncer. A substituição da lenha e outros combustíveis sólidos por combustíveis mais limpos deve ser a meta do governo para minimizar custos com a saúde.


Abstract Indoor air pollution is exacerbated by the burning of firewood in rustic stoves and poorly ventilated environments. Exposure to the pollutants emitted by this type of fuel results in increased morbidity and mortality. In Brazil, studies and estimates regarding these conditions are scarce. In order to understand this problem, the objective of this work was to investigate the use of firewood using the data series of government agencies to estimate the number of exposed people. The results indicated that firewood is the second most used fuel for cooking, being used by a significant portion of the population, more than 30 million Brazilians. A decisive factor in the increased use of this fuel is the socioeconomic level of the population associated with the price of liquefied petroleum gas (LPG). The studies carried out in the country recorded high concentrations of particles during firewood burning, exceeding the limits suggested by the World Health Organization (WHO). Associations were also observed between the exposure to the pollutants generated by the burning and the aggravation of health problems, among them respiratory diseases and cancer. Replacing fuelwood and other solid fuels with cleaner fuels should be the government's goal to minimize health costs.


Subject(s)
Humans , Environmental Monitoring/methods , Air Pollution, Indoor/analysis , Cooking/statistics & numerical data , Environmental Exposure/analysis , Respiratory Tract Diseases/etiology , Respiratory Tract Diseases/epidemiology , Socioeconomic Factors , Ventilation/standards , Wood , Brazil/epidemiology , Air Pollution, Indoor/adverse effects , Environmental Exposure/adverse effects , Neoplasms/etiology , Neoplasms/epidemiology
6.
Eng. sanit. ambient ; 24(2): 371-381, mar.-abr. 2019. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1012033

ABSTRACT

RESUMO O agravamento da poluição atmosférica nos centros urbanos devido ao crescimento das instalações industriais e da frota veicular é um problema que causa danos ambientais, afetando também a saúde humana, principalmente pela inalação de material particulado fino (MP2,5). O objetivo deste estudo foi avaliar a influência das condições meteorológicas na concentração de MP2,5 em Belo Horizonte, utilizando dados amostrados entre o inverno de 2007 e o outono de 2008. Além disso, foram avaliadas as diferenças dos dados meteorológicos e da concentração do MP2,5 entre as estações do ano nesse período. Para tanto, foram realizados testes estatísticos de correlação entre os dados meteorológicos e a concentração de MP2,5, além de análises de significância para avaliação das diferenças entre esses dois parâmetros nos períodos seco e chuvoso, característicos da área de estudo. Foi observada diferença significativa entre a concentração do MP2,5 nos períodos seco e chuvoso. Foram também observadas diferenças significativas entre os parâmetros meteorológicos (umidade relativa; temperatura mínima, média e máxima; e direção do vento) para esses períodos. Por meio da análise de correlação de Spearman, observou-se correlação significativa entre a concentração do MP2,5 e os parâmetros meteorológicos precipitação e umidade relativa do ar.


ABSTRACT The increase of air pollution in urban centres due to the growth of industrial facilities and vehicular fleet is a problem that causes environmental damage and affects human health, mainly due to the inhalation of fine particulate matter (PM2.5). For this reason, the aim of this study was to evaluate the influence of meteorological conditions on PM2.5 concentration in Belo Horizonte, using data sampled from the winter of 2007 to the autumn of 2008. In addition, the differences in meteorological data and PM2.5 concentration between the seasons of the year in this study's period were also assessed. For this, correlation statistical tests were performed for meteorological data and PM2.5 concentration, as well as significance analysis to evaluate the differences between these two parameters in the dry and wet periods, characteristic of the study area. It was observed a significant difference between PM2.5 concentration in dry and wet periods. Significant differences were also observed between meteorological parameters (relative humidity, minimum, mean and maximum temperature and wind direction) for these periods. Spearman's correlation analysis showed a significant correlation between PM2.5 concentration and the meteorological parameters precipitation and relative humidity.

7.
Rev. bras. ginecol. obstet ; 40(10): 625-630, Oct. 2018.
Article in English | LILACS | ID: biblio-977774

ABSTRACT

Abstract Improving infrastructural conditions of the in vitro fertilization laboratory, such as the air quality, has profound positive effects on embryo culture. Poor environmental conditions reduce the rate of embryo formation and, therefore, of pregnancy. This review article presents important publications regarding the impact of air quality in human reproduction laboratories on embryo quality, pregnancy success, and live births. The studies demonstrate that the replacing the air filtration system improves significantly the environmental air quality, and, consequently, improves laboratory parameters, such as the fertilization rate, the number of blastocysts, the embryo implantation rate, and the number of live births. On the other hand, improving air quality decreases the number of abortions. Therefore, environmental parameters that improve embryo quality and increase healthy child birth ratesmust be themain targets for the assisted reproduction laboratory quality control.


Resumo Melhorar as condições de infraestrutura do laboratório de fertilização in vitro, com influência na qualidade do ar, tem efeitos positivos profundos na qualidade do embrião. As más condições ambientais do ar reduzem a taxa de sucesso na formação de embriões e a taxa de gravidez. Este artigo de revisão apresenta importantes publicações sobre o impacto da qualidade do ar dentro do laboratório de reprodução humana na qualidade do embrião, no sucesso de gravidez e no número de nascidos vivos. Os estudos demonstram que a troca do sistema de filtração de ar melhora significativamente a qualidade do ar ambiente, e consequentemente, melhora os parâmetros laboratoriais, tais como a taxa de fertilização, o número de blastocistos, a taxa de implantação e o número de nascidos vivos. Por outro lado,amelhora da qualidade do ar diminui o número de abortos. Portanto, os parâmetros ambientais que melhoram a qualidade do embrião e aumentam as taxas de nascimentos de crianças saudáveis devem ser os principais alvos para o controle de qualidade do laboratório de reprodução assistida.


Subject(s)
Humans , Fertilization in Vitro/standards , Embryo Culture Techniques/standards , Environment, Controlled , Air Filters , Filtration/standards , Quality Control , Laboratories
8.
Braz. j. biol ; 78(2): 265-270, May-Aug. 2018. graf
Article in English | LILACS | ID: biblio-888859

ABSTRACT

Abstract The presence of airborne fungi in Intensive Care Unit (ICUs) is associated with increased nosocomial infections. The aim of this study was the isolation and identification of airborne fungi presented in an ICU from the University Hospital of Pelotas - RS, with the attempt to know the place's environmental microbiota. 40 Petri plates with Sabouraud Dextrose Agar were exposed to an environment of an ICU, where samples were collected in strategic places during morning and afternoon periods for ten days. Seven fungi genera were identified: Penicillium spp. (15.18%), genus with the higher frequency, followed by Aspergillus spp., Cladosporium spp., Fusarium spp., Paecelomyces spp., Curvularia spp., Alternaria spp., Zygomycetes and sterile mycelium. The most predominant fungi genus were Aspergillus spp. (13.92%) in the morning and Cladosporium spp. (13.92%) in the afternoon. Due to their involvement in different diseases, the identified fungi genera can be classified as potential pathogens of inpatients. These results reinforce the need of monitoring the environmental microorganisms with high frequency and efficiently in health institutions.


Resumo A presença de fungos anemófilos nas UTIs está associada com o aumento de infecções nosocomiais. O objetivo deste estudo foi isolar e identificar quais os principais fungos anemófilos presentes em uma Unidade de Terapia Intensiva (UTI) de um Hospital Universitário de Pelotas - RS, na tentativa de conhecer a microbiota ambiental do local. Através de 40 placas de Petri com Agar Sabouraud dextrose expostas no ambiente de UTI foram coletadas amostras por exposição em locais estratégicos durante períodos da manhã e tarde por dez dias. Sete gêneros fúngicos foram identificados: Penicillium spp. (15,18%), o gênero de maior frequência, seguido de Aspergillus spp., Cladosporium spp., Fusarium spp., Paecelomyces spp., Curvularia spp., Alternaria spp., além de Zigomicetos e micélios estéreis. Houve predomínio de Aspergillus spp. (13,92%) pela manhã e Cladosporium spp. (13,92%) a tarde. Por estarem envolvidos em diferentes enfermidades, os gêneros identificados podem ser classificados como patógenos em potencial aos pacientes internados. Estes resultados reforçam a necessidade de um monitoramento dos micro-organismos ambientais com maior freqüência e eficiência nas instituições de saúde.


Subject(s)
Humans , Air Microbiology , Fungi/classification , Intensive Care Units , Aspergillus , Cross Infection/prevention & control , Mycoses/prevention & control
9.
São Paulo; s.n; 2018. 100 p
Thesis in Portuguese | LILACS, BDENF | ID: biblio-1396048

ABSTRACT

Introdução: Recomendações nacionais (RDC ANVISA 15/2012; 50/2002) e internacionais determinam que as áreas destinadas à limpeza dos produtos para saúde (PPS) no Centro de Material e Esterilização (CME) mantenham um diferencial de pressão negativo do ar ambiente (BRASIL, 2012; AAMI, 2006; ASHARE, 2013). Entretanto, essa recomendação, até o momento, não está sustentada por estudos de alto rigor científico. Embora não houvessem justificativas explicitadas para tal recomendação, presume-se que seja prioritariamente pelo risco de transferência aérea de microrganismos, da área de limpeza para as áreas adjacentes, configurando-se em risco ocupacional. Objetivo: Avaliar o impacto da presença da pressão negativa na área de limpeza do CME mediante a avaliação da qualidade microbiológica do ar desse setor e da área de preparo dos PPS. Método: Foram comparadas amostras microbiológicas do ar coletadas da sala de limpeza (área suja) e da sala de preparo (área limpa) de dois CME classe II de um mesmo hospital localizado na cidade de São Paulo: com e sem sistema de pressão negativa do ar na área de limpeza, este último com sistema de condicionamento do ar centralizado. Como controle, foram realizadas coletas do ar exterior ao hospital. Para obter amostras microbiológicas, foi utilizado o amostrador air six-stage Andersen, com os seguintes meios de cultura seletivos e não seletivo: agar sangue, agar sabouraud, Lowenstein jensen e agar legionella. Durante a coleta do ar, foram verificadas as seguintes variáveis: temperatura e a umidade relativa dos ambientes, número de pessoas presentes e equipamentos sendo utilizados na limpeza. Após as coletas, as amostras foram encaminhadas ao laboratório de ensaios microbiológicos da escola de enfermagem da Universidade de São Paulo, onde permaneceram em estufa microbiológica regulada a 35 ± 2ºC. Os dias de incubação foram específicos para recuperação pretendida de cada grupo microbiano quais sejam: bactérias vegetativas - incluindo Legionella, Mycobacterium tuberculosis e fungos. As placas com crescimento positivo foram submetidas a identificação do gênero e/ou espécie, por meio das características fenotípicas e reações específicas, pelo laboratório de microbiologia da Santa Casa de São Paulo. As amostras, tanto do CME com pressão negativa como naquele sem, foram coletas em quintuplicata. Resultados: a concentração de bioaerossóis na área da limpeza no CME sem pressão negativa e da área de preparo foi de 273,15 e 206,71 UFC/m3 respectivamente, enquanto, no CME com pressão negativa foi de 116,96 UFC/m3 na sala da limpeza e 131,10 na de preparo. Comparando a quantidade média de colônias isoladas dos CME estudados, a diferença foi significativamente menor (p=0,01541) no CME com pressão negativa. A relação I/E, onde I é a quantidade de fungos no ambiente interior e a quantidade de fungos no ambiente exterior, no CME com pressão negativa, na sala de limpeza foi de 0,5 e na sala de preparo de 0,58. No CME sem pressão negativa, a relação foi de 0,8 e 0,6, respectivamente, na sala de limpeza e preparo, ambos abaixo do padrão de referência, que deve ser 1,5, atualmente estabelecido pela resolução nº 9/2003 da ANVISA que dispõe sobre referenciais de qualidade do ar interior, em ambientes climatizados artificialmente de uso público e coletivo. Em nenhum dos CME foram recuperados Mycobacterium tuberculosis ou Legionella do ar. Os microrganismos identificados foram Penicillium spp, Aspergillus niger, Rhodotorula spp., Bacillus subtilis, e Micrococcus spp., todos considerados como não apresentando riscos à saúde em imunocompetentes. Conclusão: Os achados da presente investigação evidenciaram que o sistema de pressão negativa na sala de limpeza do CME contribuiu para redução quantitativa de bioaerossóis, tanto nesse ambiente como na sala de preparo. Entretanto, mesmo no CME sem esse sistema de tratamento do ar na sala de limpeza, a concentração de bioaerossóis foi menos da metade do padrão referencial estabelecido pela resolução nº 9/2003 da ANVISA, em que o valor máximo permitido deve ser 750 UFC/m3 de fungos. Ressalta-se que a quantidade e tipo de microrganismos existentes em qualquer ar ambiente é circunstancial, instável e principalmente dependente dos disseminadores microbianos presentes no local, sejam pessoas ou atividades. Nesse sentido, não se condena conclusivamente CME que não dispõe de pressão negativa na sala de limpeza configurando risco ocupacional.


Introduction: National (RDC ANVISA 15/2012) and international guidelines recommend that areas for cleaning medical devices in the Material and Sterilization Center maintain a negative differential ambient air pressure (BRAZIL, 2012; AAMI, 2006; ASHARE, 2013). However, this recommendation, so far, has not been supported by highly scientifically rigorous studies. Although there are no explicit justifications for such recommendations, it can be assumed that they are grounded on the risk of airborne microorganism contamination from the cleaning area to adjacent ones, which constitutes occupational risk. Objective: to evaluate the impact of negative air pressure on the microbiological quality of the air in the Material and Sterilization Center area where medical devices are cleaned and in the adjoining preparation room. Methods: Microbiological air samples were collected from the room where medical devices are cleaned (also called dirty room) and from the room where these devices are prepared (clean room) at two class II Material and Sterilization Center in the same hospital, located in the city of São Paulo: with and without a negative air pressure system in the cleaning room; the latter with central air conditioning. As a control, outdoor air samples were collected. To obtain microbiological air samples, Andersen six-stage air sampler was used, with the following selective and non-selective culture media: blood agar, sabouraud agar, Lowenstein Jensen and agar legionella. During air collection, the following variables were controlled: temperature and air relative humidity in the rooms, number of people present in the sites and equipment used for the cleaning. After the collection, the samples were sent to the Laboratory of Microbiological Trials of the Nursing School of the University of São Paulo, where they remained in a microbiological oven at a temperature of 35ºC ± 2. The incubation period was specific for the intended recovery of each microbial group: vegetative bacteria including Legionella and Mycobacterium tuberculosis and fungi. Identification of microorganisms` genus and / or species was carried out according to their phenotypic characteristics at the Microbiology Laboratory of the Santa Casa Hospital in São Paulo. The samples, in both Material and Sterilization Center, the one with negative pressure and the one without, were collected in a five-fold sample. Results: The concentration of bioaresols in the cleaning room and preparation area without negative pressure was 273.15 and 206.71 UFC / m3, respectively, while in the Material and Sterilization Center with negative pressure the concentration of bioaerosols was 116.96 CFU / m3 in the cleaning room, and 131.10 in the preparation area. The number of isolated colonies in the negative pressure Material and Sterilization Center was significantly lower (p = 0.01541). The I / E ratio, where I is the amount of fungi in the indoor environment, and E is the amount of fungi in the outdoor environment, in the cleaning room of the negative pressure Material and Sterilization Center was 0.5, and in the preparation area, 0, 58; as for the Material and Sterilization Center without negative pressure, in the cleaning and in the preparation area, the ratio was 0.8 and 0.6, respectively, both below the reference standard currently established by ANVISA Resolution No. 9/2003, which determines indoor air quality standards at artificially climatized environments for public use. In neither of the studied Material and Sterilization Center were Mycobacterium tuberculosis or Legionella recovered from the air. The microorganisms identified were Penicillium spp, Aspergillus niger, Rhodotorula spp., Bacillus subtilis, and Micrococcus spp., all of which are considered harmless to immunocompetent subjects. Conclusion: The findings showed that the negative pressure system in the Material and Sterilization Center cleaning room contributed to the quantitative reduction of bioaerosols, both in this area and in the adjoining preparation area. However, even in the Material and Sterilization Center whose cleaning room did not have this system the concentration of bioaerosols was less than half the reference standard established by ANVISA Resolution No. 9/2003. It should be stressed that the quantity and type of microorganisms in any ambient air is circunstancial, instable and, especially dependent on microbe disseminators in the site, whether they are people or activities. Therefore, it cannot be conclusively concluded that Material and Sterilization Center that do not have negative pressure in their cleaning rooms offer occupational risk.


Subject(s)
Sterilization , Nursing , Aerosols , Air Pollution
10.
Biosci. j. (Online) ; 33(5): 1332-1339, sept./oct. 2017. tab, ilus
Article in English | LILACS | ID: biblio-966377

ABSTRACT

Hourly mean concentrations of carbon monoxide trend (CO) in the city of Rio de Janeiro (CRJ) was evaluated based on statistical tests. Air quality stations used were: Central, Copacabana, São Cristóvão and Tijuca from 2010 to 2014. The results of the CO trend based on the Mann-Kendall (MK) test showed an inverse correlation with time, with significant decrease in all seasons. Significant increase trend (Z > 0) and p-value < 0.05 were recorded in Centro and Tijuca in 2010 and 2012 with magnitude between 0.0224 and 0.0067 ppm/year. Insignificant increase occurred only in São Cristóvão (2011) for positive values (Z > 0) and p-value > 0.05. CUSUM test showed that Q magnitude did not exceed the critical value at 1% and 5% probability levels. Cumulative Sum Test (CUSUM) showed homogeneous and significant CO concentrations. Significant abrupt changes occurred in the months of May, June, July, August and September and insignificant in January, February, June, August and November at 1% and 5% probability. CO concentrations occurred in the predominant directions North-Northwest (NNW), South-Southwest (SSW) and South-west (SW). Both sectors are influenced by the main synoptic systems (Frontal System and South Atlantic Subtropical High) that act on CRJ. MK and CUSUM tests proved to be efficient in evaluating trends and abrupt changes in CO concentrations and air quality stations in the CRJ.


Foi avaliada a tendência das concentrações médias horárias de monóxido de carbono (CO), com base em testes estatísticos na cidade do Rio de Janeiro (CRJ). As estações de qualidade do ar utilizadas foram: Centro, Copacabana, São Cristóvão e Tijuca entre os anos de 2010 a 2014. Os resultados da tendência de CO com base no teste de Mann-Kendall (MK) mostrou uma correlação inversa com o tempo, com diminuição significativa em todas as estações. Tendência de aumento significativo (Z > 0) e p-valor < 0,05 foram registradas no Centro e Tijuca nos anos de 2010 e 2012 com magnitude entre 0,0224 a 0,0067 ppm/ano. Aumento insignificante ocorreu apenas em São Cristóvão (2011) para valores positivos (Z > 0) e p-valor > 0,05. O teste de SOCUM mostrou que a magnitude de Q não excedeu o valor crítico aos níveis de 1% e 5% de probabilidade. O teste das Somas Cumulativas (SOCUM) mostrou que as concentrações de CO foram homogêneas e significativas. Mudanças bruscas significativas ocorreram nos meses de maio, junho, julho, agosto e setembro e insignificante em janeiro, fevereiro, junho, agosto e novembro a 1% e 5% de probabilidade. As concentrações de CO ocorreram nas direções predominantes Norte-Noroeste (NNW), Sul-Sudoeste (SSW) e Sudoeste (SW). Ambos os setores são influenciados pelos principais sistemas sinóticos (Sistema Frontal e Alta Subtropical do Atlântico Sul) que atuam na CRJ. Os testes MK e SOCUM se mostraram eficientes na avaliação das tendências e mudanças bruscas nas concentrações de CO e nas estações de qualidade do ar existentes na CRJ.


Subject(s)
Carbon Monoxide , Air Pollution , Environmental Pollutants , Meteorology/statistics & numerical data
11.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1467059

ABSTRACT

Abstract The presence of airborne fungi in Intensive Care Unit (ICUs) is associated with increased nosocomial infections. The aim of this study was the isolation and identification of airborne fungi presented in an ICU from the University Hospital of Pelotas RS, with the attempt to know the places environmental microbiota. 40 Petri plates with Sabouraud Dextrose Agar were exposed to an environment of an ICU, where samples were collected in strategic places during morning and afternoon periods for ten days. Seven fungi genera were identified: Penicillium spp. (15.18%), genus with the higher frequency, followed by Aspergillus spp., Cladosporium spp., Fusarium spp., Paecelomyces spp., Curvularia spp., Alternaria spp., Zygomycetes and sterile mycelium. The most predominant fungi genus were Aspergillus spp. (13.92%) in the morning and Cladosporium spp. (13.92%) in the afternoon. Due to their involvement in different diseases, the identified fungi genera can be classified as potential pathogens of inpatients. These results reinforce the need of monitoring the environmental microorganisms with high frequency and efficiently in health institutions.


Resumo A presença de fungos anemófilos nas UTIs está associada com o aumento de infecções nosocomiais. O objetivo deste estudo foi isolar e identificar quais os principais fungos anemófilos presentes em uma Unidade de Terapia Intensiva (UTI) de um Hospital Universitário de Pelotas RS, na tentativa de conhecer a microbiota ambiental do local. Através de 40 placas de Petri com Agar Sabouraud dextrose expostas no ambiente de UTI foram coletadas amostras por exposição em locais estratégicos durante períodos da manhã e tarde por dez dias. Sete gêneros fúngicos foram identificados: Penicillium spp. (15,18%), o gênero de maior frequência, seguido de Aspergillus spp., Cladosporium spp., Fusarium spp., Paecelomyces spp., Curvularia spp., Alternaria spp., além de Zigomicetos e micélios estéreis. Houve predomínio de Aspergillus spp. (13,92%) pela manhã e Cladosporium spp. (13,92%) a tarde. Por estarem envolvidos em diferentes enfermidades, os gêneros identificados podem ser classificados como patógenos em potencial aos pacientes internados. Estes resultados reforçam a necessidade de um monitoramento dos micro-organismos ambientais com maior freqüência e eficiência nas instituições de saúde.

12.
Eng. sanit. ambient ; 21(2): 307-313, tab, graf
Article in Portuguese | LILACS | ID: lil-787446

ABSTRACT

RESUMO: Na Região Metropolitana do Rio de Janeiro, altos índices de concentrações de material particulado inalável (PM10) com violações dos limites estabelecidos pela Resolução CONAMA n0 03/90 são registrados rotineiramente. Analisando dados registrados entre 1998 e 2008, foram identificados 146 dias com concentrações acima dos valores estabelecidos. Nesses dias, foi possível verificar a influência da atuação do Anticiclone Subtropical do Atlântico Sul, a ausência de precipitação e a ocorrência de inversões térmicas na baixa troposfera, o que confirma a forte relação entre a ocorrência de altas concentrações de PM10 e as condições atmosféricas na região.


ABSTRACT: In the Metropolitan Area of Rio de Janeiro, high levels of particulate matter concentrations (PM10) with violations of the limits established by CONAMA Resolution 03/90 are routinely recorded. Analyzing data recorded between 1998 and 2008, 146 days with concentrations above these values were identified. In those days, it was possible to verify the influence of South Atlantic Subtropical Anticyclone, the lack of precipitation and temperature inversions in the lower troposphere, which confirm the strong relationship between high PM10 concentration and the atmospheric conditions in region.

13.
Rev. salud pública ; 18(3): 1-1, mayo-jun. 2016. ilus, tab
Article in Portuguese | LILACS | ID: lil-784964

ABSTRACT

Objetivo Avaliar a qualidade do ar das salas do centro cirúrgico de um hospital no Sul do Brasil. Métodos Foi realizada uma avaliação dos parâmetros de confortabilidade (temperatura, luminosidade, concentração de dióxido de carbono e umidade relativa do ar), análise microbiológica e cromatográfica do material particulado presente nos filtros dos aparelhos de ar condicionados. Resultados Em relação aos aspectos de confortabilidade, três salas cirúrgicas não apresentaram temperatura de acordo com a legislação vigente, mas encontram-se dentro do padrão ideal nos demais fatores ambientais. Na análise do material particulado, obteve-se um maior número de bioaerossóis fúngicos de colônias viscosas do que as filamentosas. Conclusões Constatou-se que os principais aspectos da qualidade do ar no hospital são atendidos, no entanto há a necessidade de modificação de aspectos construtivos nas salas de cirurgia para que se reduza a possibilidade de contaminações por via atmosférica e possa reduzir a concentração de dióxido de carbono no ambiente.(AU)


Objective The aim of this study was to evaluate the quality of air in surgical centre rooms of a hospital in the South of Brazil. Methods An evaluation of the parameters of comfortability (temperature, luminosity, concentration of carbon dioxide and relative humidity), microbiological analysis and chromatographic of the particulate material present in the filters of air conditioners was carried out. Results Regarding the aspects of comfortability, three surgical rooms did not present temperature in accordance to the current legislation, but were found within the ideal patterns in other environmental factors. In the analysis of particulate material, a larger number of fungal bio-aerosols of viscous colonies was obtained than filamentous. Conclusion It was found that the main aspects related to the quality of air in the hospital being studied are being accomplished; however there is a need of modifying building aspects in the surgical rooms in order to reduce the possibility of contamination by air and decrease the concentration of carbon dioxide in the environment.(AU)


Objetivo Evaluar la calidad del aire de las salas del centro quirúrgico de un hospital en el "Vale do Rio Pardo", en el sur de Brasil. Métodos Fue realizada una evaluación de los parámetros de confortabilidad (temperatura, luminosidad, concentración de dióxido de carbono y humedad relativa del aire), análisis microbiológico y cromatográfico del material particulado presente en los filtros de los aparatos de aire acondicionados. Resultados En relación a los aspectos de confortabilidad, tres salas quirúrgicas no presentaron temperatura de acuerdo con la legislación vigente, pero se encuentran dentro del padrón ideal en los demás factores ambientales. En el análisis del material particulado, se obtuvo un número más grande de bioaerosoles fúngicos de colonias viscosas de que las filamentosas. Conclusión Se constató que los principales aspectos relacionados a la calidad del aire en el hospital en estudio, son atendidos, sin embargo, ahí la necesidad de cambio de aspectos constructivos en las salas de cirugía para que se reduzca la posibilidad de contaminaciones por vía atmosférica y pueda reducir la concentración de dióxido de carbono en el ambiente.(AU)


Subject(s)
Operating Rooms/standards , Carbon Dioxide/analysis , Cross Infection/prevention & control , Air Pollution, Indoor/analysis , Brazil , Microbiological Techniques/instrumentation
14.
São Paulo; s.n; 2014. [156] p. ilus, map, tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-870810

ABSTRACT

Bases científicas para o entendimento dos efeitos da poluição atmosférica sobre a saúde humana são ainda necessárias em todo o mundo, considerando que os dados locais devem ser utilizados como parâmetro para tomada de decisão e controle da poluição do ar. Países em desenvolvimento carecem de tecnologia para detecção e mensuração dos níveis de poluição do ar, o que dificulta a atualização de legislação sobre padrões da qualidade do ar para o controle das fontes emissoras. Diversas abordagens metodológicas tem sido sugeridas por agências internacionais, no entanto para o contexto local faz-se necessário adaptações que resulte em métodos replicáveis pelas agências brasileiras. No Brasil, o Ministério da Saúde, através da Vigilância em Saúde Ambiental, estimula o desenvolvimento de metodologias que possam viabilizar a implementação do programa de vigilância em saúde relacionada à qualidade do ar. O objetivo deste estudo foi aplicar a metodologia de análise de riscos para avaliar a qualidade do ar na cidade de Salvador e o impacto sobre a saúde, na perspectiva de implantação de ações da Vigilância em Saúde Ambiental. Este estudo se caracteriza como ciência no contexto da ação. Foram realizados dois estudos para aplicação da metodologia proposta. No primeiro estudo, em fase de identificação do perigo, os poluentes foram caracterizados em termos de sua composição química, utilizando a técnica de biomonitoramento como ferramenta alternativa para acessar as partículas presentes na atmosfera urbana. Para a detecção de metais no material particulado foram utilizadas técnicas analíticas de espectrofotometria de absorção atômica e para a análise morfológica destas partículas foram utilizadas técnicas de microscopia eletrônica de varredura convencional e micro análises de raios-x. A composição química do material particulado foi estudada para entendimento das emissões locais. No segundo estudo, além da identificação do contaminante e caracterização do risco foi também...


Scientific bases for understanding the effects of atmospheric pollution on human health are still necessary in all parts of the world, considering that local data should be used as a parameter for decision-making and the control of air pollution. Developing countries lack the technology to detect and measure levels of air pollution, making it difficult to update legislation on air quality standards for the control of emission sources. Several methodological approaches have been suggested by international agencies, however for the local context it is necessary to make adjustments that will result in replicable methods across Brazilian agencies. In Brazil, the Ministry of Health, through the Environmental Health Surveillance, stimulates the development of methodologies that can facilitate the implementation of a health surveillance program related to air quality. The objective of this study was to apply risk analysis methods to evaluate the air quality of the city of Salvador and its impact on health, from the perspective of the Environmental Health Surveillance's regulatory actions. This study is characterized by science and decision. Two studies were conducted that applied the proposed methods. In the first study, during the hazard identification phase, pollutants were characterized in terms of their chemical composition using a biomonitoring technique as an alternative tool to access the particles present in the urban atmosphere. The analytic techniques of atomic absorption spectrophotometry were used for the detection of metals in the particulate matter, and for the morphologic analysis of these particles, conventional scanning electron microscopy and X-ray microanalysis techniques were used. The chemical composition of the particulate matter was then studied to understand local emissions. In the second study, in addition to contaminant identification and risk characterization, human health exposure was also evaluated. Risk communication strategies were use...


Subject(s)
Air Pollutants , Air Pollution , Air Pollution , Decision Making , Environmental Health , Environmental Health Surveillance , Environmental Monitoring , Microscopy, Electron , Risk Assessment , Spectrophotometry, Atomic
15.
Eng. sanit. ambient ; 19(spe): 43-50, 2014. tab, graf
Article in Portuguese | LILACS | ID: lil-732476

ABSTRACT

A preocupação com a gestão da qualidade do ar na cidade do Rio de Janeiro tem aumentado nos últimos anos devido aos grandes eventos que a cidade irá receber em um futuro próximo. A utilização de Sistema de Informação Geográfica como uma ferramenta para a gestão da qualidade do ar foi avaliada neste trabalho. Foi feita uma nova delimitação das bacias aéreas com a utilização de dados digitais que proporcionou o surgimento de três novas bacias aéreas e a alteração da configuração espacial das bacias aéreas existentes.


The concern with the air quality management in the city of Rio de Janeiro has increased in recent last years due to the great events that this city will receive in the near future. The use of a Geographic Information System as a tool for the air quality management was evaluated in this work. A new delimitation of air basins was proposed using the digital data suggesting the appearance of three new air basins and the change of the spatial configuration of the existing air basins.

16.
Eng. sanit. ambient ; 19(spe): 31-42, 2014. tab, graf
Article in Portuguese | LILACS | ID: lil-732477

ABSTRACT

O aumento da frota veicular causa a deterioração da qualidade do ar e o comprometimento da saúde e bem-estar da população. A malha urbana edificada influencia o escoamento do ar, dificultando a dispersão de emissões veiculares. O presente estudo objetiva avaliar a influência dos parâmetros de ocupação do solo definidos pela legislação municipal nos eixos estruturais em Curitiba (PR), caracterizados pelo forte estímulo ao adensamento e alto tráfego veicular. Foram simuladas variações do recuo frontal e das alturas das edificações nestes eixos, em especial na Avenida Sete de Setembro, a fim de verificar a influência destes na concentração de poluentes. São feitas sugestões de possíveis alterações à legislação em vigor, recomendando-se reduzir a altura das edificações no lado oposto ao vento predominante e aumentar, nos trechos não consolidados, o recuo frontal da sobreloja.


The increase in the number of vehicles causes deterioration of air quality and decline of population health and well-being. The urban grid of buildings influences air flow, hampering the dispersion of vehicular emissions. The present study aims to assess the influence of land use parameters defined by local legislation, at the Structural Axes in Curitiba (PR), which are characterized by strong stimulus both to high urban density and vehicular traffic. Variations in building setback front line and height were considered, specifically on Avenida Sete de Setembro, in order to investigate their influence on pollutant concentration. The conclusion includes suggestions for modifications in the current city by-laws of land use, recommending that building height be reduced on the side opposite to prevailing winds, and increasing, in yet not consolidated stretches, the frontal setback of mezzanines.

17.
Rev. saúde pública ; 47(6): 1059-1068, dez. 2013. tab
Article in Portuguese | LILACS | ID: lil-702729

ABSTRACT

OBJETIVO : Analisar a qualidade do ar em escolas de educação básica e suas condições estruturais e funcionais. MÉTODOS : Foi avaliada a qualidade do ar de 51 escolas (81 salas de aula) de educação básica da cidade de Coimbra, Portugal, tanto na parte interior das salas como na exterior, durante as quatro estações do ano, de 2010 a 2011. Foram avaliadas a temperatura (Tº), umidade relativa (Hr), concentrações de monóxido de carbono (CO), dióxido de carbono (CO 2 ), ozona (O 3 ), dióxido de nitrogênio (NO 2 ), dióxido de enxofre (SO 2 ), compostos orgânicos voláteis (COV), formaldeído e material particulado (PM 10 ), de novembro de 2010 a fevereiro de 2011 (outono/inverno) e de março de 2011 a junho de 2011 (primavera/verão). Procedeu-se ao preenchimento de uma grelha de caracterização das condições estruturais e funcionais das escolas. Aplicaram-se os testes estatísticos t- Student para amostras emparelhadas e o teste t de Wilcoxon. RESULTADOS : Em 47 escolas, as concentrações médias de CO 2 encontravam-se acima da concentração máxima de referência (984 ppm) mencionada na legislação portuguesa. Os valores máximos de concentração encontrados no interior das salas foram críticos, principalmente no outono/inverno (5.320 ppm). As concentrações médias de COV e de PM 10 no interior ultrapassaram a concentração máxima de referência legislada em algumas escolas. Não foram detetados valores relevantes (risco) de CO, formaldeído, NO 2 , SO 2 e O 3 . CONCLUSÕES : Houve maior concentração de poluentes no interior das salas, comparativamente com o exterior. A inadequada ventilação está associada à elevada concentração de CO 2 nas salas de aula. .


OBJETIVO : Analizar la calidad del aire en escuelas de educación básica y sus condiciones estructurales y funcionales. MÉTODOS : Se evaluó la calidad del aire de 51 escuelas (81 salas de aula) de educación básica de la ciudad de Coimbra, Portugal, tanto en el interior de las salas como en el exterior, durante las cuatro estaciones del año, de 2010 a 2011. Se evaluaron la temperatura (T°), humedad relativa (Hr), concentraciones de monóxido de carbono (CO), dióxido de carbono (CO2), ozono (O3), dióxido de nitrógeno (NO2), dióxido de azufre (SO2), compuestos orgánicos volátiles (COV), formaldehido (HCHO) y material particulado (PM10), de noviembre de 2010 a febrero de 2011 (otoño/invierno) y de marzo de 2011 a junio de 2011 (primavera/verano). Se procedió a llenar una tabla de caracterización de las condiciones estructurales y funcionales de las escuelas. Se aplicaron las pruebas estadísticas t-Student para muestras pareadas y la prueba t de Wilcoxon. RESULTADOS : En 47 escuelas, las concentraciones promedio de CO2 estaban por encima de la concentración máxima de referencia (984 ppm) mencionada en la legislación portuguesa. Los valores máximos de concentración encontrados en el interior de las salas fueron críticos, principalmente en el otoño/invierno (5.320 ppm). Las concentraciones promedio de COV y de PM10 en el interior sobrepasaron la concentración máxima de referencia legislada en algunas escuelas. No fueron detectados valores relevantes (riesgo) de CO, HCHO, NO2, SO2 y O3. CONCLUSIONES : Hubo mayor concentración de contaminantes en el interior de las salas, en comparación con el exterior. La inadecuada ventilación está asociada con la elevada concentración de CO2 en las salas de aula. .


OBJECTIVE : To analyze the air quality in elementary schools and their structural and functional conditions. METHODS : Air quality in 51 elementary schools (81 classrooms) in the city of Coimbra, Portugal, both inside and outside of the rooms was evaluated during the four seasons, from 2010 to 2011. Temperature (T°), relative humidity (Hr), concentrations of carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), compounds were evaluated, as were volatile organics (VOC), formaldehyde and particulate matter (PM10), from November 2010 to February 2011 (autumn/winter) and March 2011 to June 2011 (spring/summer). A grid characterizing the structural and functional conditions of the schools was created. The statistical Student t test for paired samples and the Wilcoxon t test were applied. RESULTS : In 47 schools, the average CO2concentrations were above the maximum reference concentration (984 ppm) mentioned in Portuguese legislation. The maximum concentration values found inside the rooms were critical, especially in the fall/winter (5,320 ppm). In some schools the average concentrations of VOC and PM10within the maximum concentration exceeded the reference legislated. The values (risk) of CO, formaldehyde, NO2, SO2and O3detected were not relevant. CONCLUSIONS : There was a higher concentration of pollutants inside the rooms compared with outside. Inadequate ventilation is associated with high CO2concentration in the classroom. .


Subject(s)
Air Pollutants/analysis , Air Pollution, Indoor/analysis , Schools/statistics & numerical data , Air Pollutants/chemistry , Air Pollution, Indoor/statistics & numerical data , Carbon Dioxide/analysis , Carbon Monoxide/analysis , Nitrogen Dioxide/analysis , Portugal , Risk Assessment , Seasons
18.
J. Health Sci. Inst ; 30(1): 48-52, jan.-mar. 2012.
Article in Portuguese | LILACS | ID: lil-644795

ABSTRACT

Nos últimos anos, o ar tem recebido uma atenção especial por parte dos pesquisadores, por conter partículas químicas, físicas ou biológicas que podem pôr em risco a vida das pessoas. A infecção hospitalar (IH) é um problema de saúde pública e estudos relatam que a contaminação dos sistemas de ar condicionado tem sido uma importante fonte de distribuição de microrganismos. Frente a isso, buscaram-se analisar através de uma revisão integrativa, estudos sobre a qualidade do ar dos centros cirúrgicos (CC) e sua relação com IH. Para tanto, perguntou-se: Como está a qualidade do ar nos CC? Essa qualidade tem influenciado a incidência de IH? Assim, os objetivos deste estudo foram caracterizar as publicações produzidas sobre a IH no CC; sintetizar as informações mais relevantes e identificar a contribuição da enfermagem no controle da IH no CC. O levantamento bibliográfico foi realizado via internet, utilizando as palavras-chave: "centro" + "cirúrgico"+ "ar"+ "infecção" + "hospitalar", encontrando-se 09 referências, após os critérios de exclusão e inclusão. No Brasil, há uma crescente preocupação em relação à qualidade do ar, mas são poucos os estudos realizados sobre esse contexto, especialmente em relação às publicações de enfermagem. Esta revisão mostrou uma trajetória em relação ao ambiente aéreo e traz considerações importantes a respeito do controle do ar. Conclui-se que, quando controlado todos os mecanismos de intervenção do ar pode-se prevenir surtos de IH e contribuir na diminuição da estadia hospitalar, custos e melhora na qualidade de vida.


Currently, the air has received special attention from researchers, because contain chemical, physical or biological particles that could endanger people's lives. The hospital infection (HI) is a public health problem and studies report that the contamination of air conditioning has been an important source of distribution of microrganisms. Due to this fact, we have analyzed through an integrative review of studies on air quality of surgical centers (SC) and its relationship to HI. Then, we ask: How is the air quality in SC? This quality has influenced the incidenceof HI? The objectives of this study were to characterize the publications produced on HI in SC; synthesize the most relevant information and identify the contribution of nursing to control HI at SC. The bibliographic research was conducted in internet using the keywords "heart", "surgical", "air", "infection", "hospital". It was found 09 references, after the inclusion and exclusion criteria. In Brazil, there is growing concern about air quality, but there are few studies of this context, especially in relation to nursing publications. This review showed a trend towards the environment air and brings important considerations about the control of the air. We conclude that, after controlling all the mechanisms of action of the air can prevent outbreaks of hospital infection and contribute to decreasing the hospital stay, costs, and improved quality of life.


Subject(s)
Humans , Air Pollution , Cross Infection/diagnosis , Cross Infection/etiology , Surgery Department, Hospital
19.
Eng. sanit. ambient ; 16(4): 387-394, out.-dez. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-614703

ABSTRACT

Este estudo tem por objetivo verificar as associações de curto prazo entre as concentrações de poluentes atmosféricos e a mortalidade de idosos no município de Curitiba (PR). O período de análise compreendeu os anos de 2003 a 2008. Foram realizadas análises de correlação simples e de regressão múltipla, utilizando-se um modelo aditivo generalizado (MAG), para avaliar as relações entre os poluentes dióxido de enxofre (SO2), ozônio (O3) e partículas totais em suspensão (PTS) e o número de óbitos totais (ObT) e por doenças respiratórias (ObR) de pessoas com idade superior a 60 anos. Os resultados obtidos mostraram relações positivas e estatisticamente significativas entre os níveis de PTS e a mortalidade de idosos por todas as causas (ObT), mesmo considerando-se que os níveis de PTS atenderam aos padrões de qualidade do ar para o período em estudo.


This study aims to analyze the short-term association between concentration of atmospheric pollutants and the mortality of elderly in the city of Curitiba (Brazil). The data comprised the period from 2003 to 2008. The relationships between the pollutants sulfur dioxide (SO2), ozone (O3) and total suspended particles (TSP) and the number of total deaths (ObT) and deaths due to respiratory deceases (ObR) of people aged over 60 years were investigated with simple correlation and multiple regression analyses, using a generalized additive model (GAM). The results showed a positive and statistically significant relationship between TSP concentrations and elderly mortality from all causes (ObT), even considering that TSP concentrations met the air quality standards during the period of study.

20.
Ciênc. Saúde Colet. (Impr.) ; 16(8): 3583-3590, ago. 2011. tab
Article in Portuguese | LILACS | ID: lil-595947

ABSTRACT

A Qualidade do Ar Interno (QAI) surgiu como ciência a partir da década de 70 com a crise energética e a consequente construção dos edifícios selados (desprovidos de ventilação natural), principalmente nos países desenvolvidos, e se destacou após a descoberta de que a diminuição das taxas de troca de ar nesses ambientes era a grande responsável pelo aumento da concentração de poluentes no ar interno. Admite-se que a ventilação seja um dos principais fatores que interferem na qualidade do ar interno e que os próprios ocupantes dos edifícios contribuem substancialmente com a poluição destes ambientes através de suas atividades. Sabe-se ainda que a má qualidade do ar interno está associada a doenças (como tosse, rinite, alergia, etc.) e à Síndrome dos Edifícios Doentes (SED). Para amostragem de substâncias gasosas no ar de ambientes internos dispõe-se de diversas metodologias, sendo as principais: sistemas passivos de monitoramento, sistemas ativos e automáticos. Para a efetiva promoção de um ambiente saudável, deve-se conciliar a aplicação de legislações específicas com pesquisas e conscientização dos ocupantes dos edifícios. Essa revisão objetiva relacionar os diferentes contaminantes encontrados em ambientes internos, seus efeitos à saúde humana e suas metodologias de amostragem.


Indoor Air Quality (IAQ) emerged as a science from the 1970s onwards with the energy crisis and the subsequent construction of sealed buildings (without natural ventilation). This mainly occurred in developed countries and it soon came to public attention that lower levels of air exchange in these environments was the main culprit for the increase in concentration of indoor air pollutants. It is common knowledge that ventilation is one of the principal factors that interfere with air quality in indoor environments and that the occupants contribute to the pollution of these environments with their activities. Furthermore, poor indoor air quality is associated with some diseases (cough, rhinitis, allergy, etc.) and with Sick Building Syndrome (SBS). For sampling of the indoor contaminants there are several methodologies, available including passive monitoring systems, active and automatic systems. To ensure a healthy indoor environment, the application of specific legislation needs to be reconciled with research and fostering awareness among the occupants of such buildings. This survey seeks to identify the different contaminants found in internal environments, their effects on human health and the methodologies available for sampling them.


Subject(s)
Humans , Air Pollution, Indoor/adverse effects , Sick Building Syndrome/etiology
SELECTION OF CITATIONS
SEARCH DETAIL